UA RU EN
Get in touch

No guesswork during an outage

Source

See the power source at a glance

Grid, battery or generator, shown with a coloured ring. No trips to the panel and no need to open the inverter app.

Battery

Charge and time left

Charge level, charge or discharge power and how many hours the battery will last at the current load.

Load

A warning before overload

The display shows inverter and generator load in percent. When it gets close to the limit, it lights up, a hint not to run the water heater and the oven at the same time.

Generator

Fuel, run hours, service

Tank level, run hours and a reminder to change the oil on the manufacturer's schedule.

Telegram

Alerts for what matters

Power lost and restored, low battery, generator start, low fuel, overload. The whole family in one chat.

Automation

Heavy loads switch off by themselves

When the battery runs low or the inverter or generator nears overload, the water heater, air conditioner and underfloor heating switch off automatically, and back on when grid power returns.

History

How long the outages lasted

Duration of each outage, how much energy the battery supplied and how many hours the generator ran.

Build your display from the options you need

Turn on the options you need and see how the displays change. The basics — power source, battery and load — are always there when we read data from the inverter.

Tap an option to turn it on or off — the displays will change.

Battery64%≈5 h · 1.4 kW
Round 1.28″
SourceBattery
Battery64%
Time left≈5 h
Load1.4 kW
Generatoroff
Square 4″
SourceBattery
Battery64%
Time left≈5 h
Load1.4 kW
Generatoroff
Panel 7″
Generator

Adds: generator status and load in percent, with an overload warning

Needs: on Deye, the inverter GEN port; if the generator feeds the inverter input through a transfer switch, a Shelly EM meter on the grid feed

We read the inverter without cutting a single wire

We install the SDS gateway, an industrial DIN-rail controller with RS485, in your distribution board. It reads data from the Deye inverter through a separate RS485 (Modbus) port, which most hybrid models have, in read-only mode: it never changes inverter settings, and the Deye Wi-Fi logger and app keep working as before. We check the port against your inverter model. The displays refresh every 2–3 seconds. If the link drops for more than a few seconds, the display says so instead of showing an old number.

Power monitor diagram The grid and the generator feed a Deye inverter with a battery. The SDS gateway in the distribution board reads the inverter over RS485 and the fuel level from a sensor in the generator tank, then sends the status to the room displays and to Telegram over the internet. RS485 fuel level sensor internet Gridsingle- or three-phase GeneratorDeye GEN port Deye inverterhybrid, 1- or 3-phasestarts the generatorby battery charge LiFePO4 batteryBMS data via inverter SDS gatewayindustrial controllerESP32 + RS485, DIN Displaysin rooms Telegramover the internet
power linesinverter datasensor and gateway signals

The gateway, router and displays must run from the inverter output, otherwise they go dark with the lights during an outage. If the generator is connected through a transfer switch to the grid input rather than to the GEN port, we add a Shelly EM meter on the grid feed (a Shelly Pro 3EM for three phases), so the display knows the grid is back even before the switch-over. In a metal distribution board the gateway gets an external antenna.

Fuel and run hours without walking to the tank

Fuel level

A sensor in the generator tank or a separate tank

We pick the sensor type for your tank: float or capacitive; for petrol generators a separate fuel tank is sometimes easier. Percent and approximate litres on the display, with alerts at 30% and 15% and an estimate of how many hours are left at the current load.

Run hours

Counted automatically

The gateway sees when the generator is producing voltage and keeps a counter. It may differ slightly from the generator's own hour meter. You get a reminder before the oil change is due.

Auto start

The generator starts on its own

Deye starts the generator when the battery drops to a set level and stops it once the battery is charged. This needs a generator with an electric starter and two-wire remote start, or an auto-start module. The monitor logs every start, the battery charge at that moment and the run time.

Load

No generator overload

Generator load as a percent of its rated power. When it gets close to the limit, the display shows a warning.

Generator monitoring in detail →

A display for every room

1.28″

Round, surface-mounted

bedroom, kids' room, study
  • 240×240 with a coloured status ring
  • USB-C power from a plug adapter
  • wall mount without drilling
  • optional battery: a few hours of runtime if the socket is not on the inverter
4″

Square panel in a wall box

hallway, kitchen
  • 480×480 touch screen, six data tiles
  • fits a deep 60 mm wall box or an 86×86 box
  • built-in 230 V power supply, needs a neutral wire
  • a relay version can replace a light switch
7–10″

Control panel

living room, utility room
  • the full energy picture of your home
  • charge and outage charts
  • can be combined with a smart home
  • wall or desk mount
Shelly

Shelly Wall Display

ready-made and affordable
  • 4″ Android touch screen in a wall box
  • built-in relay and temperature sensor
  • shows a Home Assistant dashboard with all the data
  • Home Assistant can also switch off the water heater and other loads on low battery or overload
  • needs Home Assistant — we set it up on a mini PC

Your phone shows the same data: Telegram has a «Status» button (the /status command), and we can connect Home Assistant if you use it.

What we need to know

Inverter

Deye model

A photo of the inverter label, single- or three-phase, battery capacity.

Generator

How it is connected

Inverter GEN port or a transfer switch on the input. Generator model and whether it has an electric starter.

Displays

How many and where

Which rooms need a display and whether there are deep wall boxes or 86×86 boxes.

We give an exact price after a site survey. A site visit costs from 1,500 UAH in Kyiv and from 2,000 UAH in Kyiv Oblast; this amount is credited toward the job.

Deye and generator monitoring FAQ

Will it work if I don't have a Deye?

This page covers Deye because it is the inverter we install most. Other hybrid inverters with an RS485 (Modbus) port can be read too, but the data available depends on the model. Send us the model and we will tell you what you will see.

Could the gateway change my inverter settings?

No. The gateway only reads inverter registers and never writes to it. The Deye Wi-Fi logger and app keep working as before.

Do the displays work without internet?

Yes. The gateway sends the status to the displays directly; internet is only needed for Telegram. Just make sure the gateway, displays and router run from the inverter.

Can I use it without a generator?

Yes. The display then shows the grid and the battery, and the generator section is hidden. A fuel sensor and run-hour tracking can be added later.

How accurate is the time-left estimate?

It is accurate for lithium batteries that report BMS data to the inverter. With lead-acid batteries the charge is estimated from voltage, so the estimate is rough.

How much does it cost?

It depends on the number of displays and whether you need a fuel sensor. We give an exact price after a site survey. A site visit costs from 1,500 UAH in Kyiv and from 2,000 UAH in Kyiv Oblast; this amount is credited toward the job.

No backup power yet? Turnkey backup power →

Tell us what needs doing and we'll get back to you during business hours

Send a request

Tell us about the job in a short form — from replacing a smart relay to a full rewire. We'll send a preliminary estimate within a day.

Phone

+38 (068) 989-33-93
+38 (073) 989-33-93

Message us:
Call us

Telegram

@sds_kiev

Message us

Email

info@sds.kiev.ua

Send an email

Address

29 Pryrichna St, Kyiv

View on map
Call us